Es scheint, dass Sie die Website nicht mit den richtigen Einstellungen für Ihr Land besuchen. Möchten Sie zur richtigen Version der Website wechseln?

Weiter Schließen und mit den aktuellen Einstellungen fortfahren

Manley STEREO VARIABLE MU

Vari-Mu Stereo Limiter Compressor

Manley Laboratories
SKU: 20284

4.583,00 € 3.851,26 + VAT

  • Verfügbar
  • Clock icon Normalerweise versandt in 8-10 Arbeitstage

Manley STEREO VARIABLE MU

Vari-Mu Stereo Limiter Compressor

Tube dual channel ideal for tracking vocals, acoustic instrument. Also really nice on your final mix, or 2-track mastering limiting and compression

Specifications

  • MANLEY input & output transformers with nickel laminations in mu-metal cases with flat frequency response from 20Hz-25KHz
  • BALANCED INPUTS & OUTPUTS (600 Ohms)
  • Fully differential ALL-TUBE circuitry using one each 5670, 5751 (or 12AX7), 7044 (or 5687), & 12AL5 per channel
  • Independently regulated B+ and Heater supplies
  • Hard-wire BYPASS switch
  • Stepped switch INPUT attenuator as of 10/2011. (older units use Silent dual-ganged potentiometer)
  • RECOVERY 5 steps: 0.2s, 0.4s, 0.6s, 4sec., 8sec.
  • Variable ATTACK: 25msec-70msec
  • Continuously variable THRESHOLD
  • LIMIT (4:1 to 20:1) or COMPRESS (1.5 to 1)
  • HP SC: High Pass Side Chain Filter -3dB @ 100Hz
  • Large ILLUMINATED Sifam METERS (older units before serial number MSLC61642 shipped before 12/2003 use: 26V 1.2W FESTOON LAMPS; Manley's Part Number: VAR016B) Order spare bulbs using our parts order form. (newest units after serial number MSLC61642 shipped after 12/2003 use white LED lighting)
  • STEREO LINK SWITCH
  • Several units can be linked for Surround (custom order )
  • Maximum gain: 35dB
  • Max. output: +30dBu (26Vrms) 26dB Headroom
  • <0.1% THD @ 1KHz Noise floor: -85dB typical
  • Power Consumption (120/240VAC): 80 watts
  • Unit is factory set for 100V, 120V or 220-240VAC operation for original destination country's mains voltage.
  • Operating Mains Voltage changeable with power transformer changeover switch and fuse value change.
  • Mains Fuse Value for 100~120VAC operation:replace with 1.25A as of 10/2011
  • Mains Fuse Value for 220~240VAC operation: replace with 0.6A (600mA) as of 10/2011
  • Mains Fuse Type: MDA or MDL SLO-BLO Time delay 1 1/4" x 1/4"
  • Mains Voltage Frequency: 50~60Hz
  • Dimensions: 19” x 3 1/2” x 10” (chassis occupies 2u) Power transformer protrudes 3.5" out the back of the chassis.
  • Shipping Weight: 23 lbs.

Channels

2 (Stereo)

Hardware format

Rack

Ihr Warenkorb

Leerer Wagen

Länder und Sprachen